HORIBA – LAQUA Act - pH/ORP/Temperature (PH 110, 120, 130)
Category: Laboratory Equipments
Specifications
Details
HORIBA – LAQUA Act - pH/ORP/Temperature (PH 110, 120, 130)
Brand: Horiba
Model: PH 110, 120, 130
Specifications:
| Model |
PH110 pH/ORP/Temperature (°C) |
PH120 pH/ORP/Temperature (°C) |
PH130 Dual Channel pH/ORP/Ion/Temperature (°C) |
| pH Range | -2.00 to 16.00 pH | -2.00 to 16.00 pH | -2.00 to 16.00 pH |
| Resolution | 0.01 pH | 0.01 pH | 0.01 pH |
| Accuracy | ± 0.01 pH | ± 0.01 pH | ± 0.01 pH |
| Calibration Points | 5 | 5 | 5 |
| Buffer Options | USA, NIST | USA, NIST, Custom | USA, NIST, Custom |
| ORP Range | ± 2000 mV | ± 2000 mV | ± 2000 mV |
| Resolution | 1 mV | 1 mV | 1 mV |
| Accuracy | ± 1mV or 1% of reading (whichever is greater) | ± 1mV or 1% of reading (whichever is greater) | ± 1mV or 0.2% of reading (whichever is greater) |
| Ion range | - | - | 0.000 μg/L to 1999 g/L |
| Resolution | - | - | 4 significant digits |
| Accuracy | - | - | ±0.8% full scale |
| Calibration Points | - | - | Up to 5 |
| Temperature Range | -30.0°C to 130.0°C | -30.0°C to 130.0°C | -30.0°C to 130.0°C |
| Resolution | 0.1°C | 0.1°C | 0.1°C |
| Accuracy | ± 0.4°C | ± 0.4°C | ± 0.4°C |
| Calibration Option | Yes | Yes | Yes |
| Memory | 100 | 1000 | 1000 |
| Auto Data-logging | - | Yes | Yes |
| Real time clock | - | Yes | Yes |
| Date/ time stamping | - | Yes | Yes |
| Auto-Shut Off |
Yes (Programmable: 1 to 30 minutes) |
Yes (Programmable: 1 to 30 minutes) |
Yes (Programmable: 1 to 30 minutes) |
| Auto-Hold | Yes | Yes | Yes |
| Averaging/ Stability | Yes, Automatic | Yes, Automatic | Yes, Automatic |
| Offset | Yes | Yes | Yes |
| Slope Display |
Yes (Independent acid and alkaline slopes depending on calibration) |
Yes (Independent acid and alkaline slopes depending on calibration) |
Yes (Independent acid and alkaline slopes depending on calibration) |
| Electrode Status | On screen display | On screen display | On screen display |
| Diagnostic Messages | Yes | Yes | Yes |
| Display | Custom LCD | Custom LCD with backlight | Custom LCD with backlight |
| Inputs | BNC, phono, DC sockets | BNC, phono, DC sockets | 2 x BNC, 2 x phono, DC sockets |
| Outputs | - | RS232C | RS232C |
| IP Rating | IP67, shock-resistant | IP67, shock-resistant | IP67, shock-resistant |
| Power Requirements | 2 x ‘AAA’ or LR03 or Ni-MH rechargeable batteries or power adaptor | 2 x ‘AAA’ or LR03 or Ni-MH rechargeable batteries or power adaptor | 2 x ‘AAA’ or LR03 or Ni-MH rechargeable batteries or power adaptor |
| Battery Life | >1000 hours | >1000 hours | >500 hours |
| Kit* includes: |
PH110-K Waterproof pH/ORP handheld meter (3999960167) · PH110 meter · 9651-10D plastic-body, gel-filled pH electrode · pH 4.01, 7.00, 10.01 solutions (60ml) · carry case |
PH120-K Waterproof pH/ORP handheld data meter (3999960168) · PH120 meter · 9651-10D plastic-body, gel-filled pH electrode · pH 4.01, 7.00, 10.01 solutions (60ml) · carry case |
PH130-K Waterproof pH/ORP/Ion handheld data meter (3999960169) · PH130 meter · 9651-10D plastic-body, gel-filled pH electrode · pH 4.01, 7.00, 10.01 solutions (60ml) · carry case |
View more about HORIBA – LAQUA Act - pH/ORP/Temperature (PH 110, 120, 130) on main site